The Building Regulations for a loft conversion, in plain language
Building Regulations for loft conversions are not complicated once you strip out the acronyms. Six things matter, and they are all connected.
One: means of escape. Above ground-floor bedrooms need a protected escape route, which means a fire-rated staircase enclosure and fire-rated doors on every habitable room off the stair. Not optional.
Two: the staircase pitch and headroom. The stair pitch cannot exceed 42 degrees. Minimum headroom above the pitch line is 1.9m at the centre and 1.8m at the sides. This is what most loft conversions have to design around.
Three: floor loading and joist sizing. The existing ceiling joists are not floor joists. New joists sized to the loading are always needed.
Four: insulation. Cold roof or warm roof, either approach is fine, but the U-value target is set. On a typical dormer conversion this means 100mm to 150mm of insulation between and under the rafters.
Five: dormer sizing and roof geometry. Dormers have a maximum permitted size under permitted development, and there are rules for how close to the eaves they can sit. A rear dormer on a two-storey house typically falls under permitted development. A front dormer typically needs full planning.
Six: fire protection to the loft floor. The floor of the loft has to give 30-minute fire resistance from the room below. This is achieved with 15mm plasterboard on the ceiling side and appropriate insulation between the joists.